Manufacturer record

Hi Tech International: regulatory record

Last checked 20 September 2026. Source: CDSCO monthly NSQ alerts and state drug-testing laboratories

3 batches manufactured by Hi Tech International (Haryana) were declared Not of Standard Quality between April 2020 and April 2020. Records are batch-specific findings by government laboratories as published in CDSCO's monthly alerts; where a company has stated that a flagged batch was counterfeit, that statement is noted when reported.

Records by type

3 records linked to Hi Tech International in the datasets we hold. A zero means nothing is on record in those datasets, not that nothing ever happened. What the labels mean.

0Banned or prohibited
0Recalled or suspended
3Failed a lab test
0Regulatory notice
Primary government sourceTier 1: government primary source

CDSCO drug alerts: Not of Standard Quality and spurious drugs

CDSCO · CDSCO monthly NSQ alerts, Apr 2020 to Apr 2020

View original document

Scope. A company appearing here is not a finding that its products are unsafe. Regulatory actions can apply to one batch, one formulation, one period or one state. Always check the linked government document for the current position, and tell us if something is out of date. How we label records.

3
NSQ batches since 2020
2
Products affected
Identification
Most common failure
Apr 2020
Latest alert

Flagged batches per year

2020 · 3

All flagged batches

Product Batch Reason declared NSQ Tested by Alert
Viro-Rub Hand Sanitizer Alocohol Hand Rub 20208878Mfg 2020-03 · Exp 2024-03 Identification of Ethyl Alcohol Remarks:- Sample contains 08.52%v/v Methanol and 54.33%v/v of isopropyl alcohol where as the label claim is more than 75%v/v Ethyl Alcohol IPIdentification RDTL ChandigarhState lab Apr 2020
Viro-Rub Hand Sanitizer Alocohol Hand Rub 20208878Mfg 2020-03 · Exp 2024-03 Identification of Ethyl Alcohol Remarks:- 1) Sample contains 10.11%v/v Methanol and 46.17%v/v of isopropyl alcohol where as the label claim is more than 75%v/v Ethyl Alcohol IP 2) Color is not stable, it disappearing on storage 3) Few bottles are mentioned marketed by Hi Tech International, 18, Sector 6 Manesar Gurgaon, India instead of mfd by.Identification RDTL ChandigarhState lab Apr 2020
Viro-Rub Hand Sanitizer Alcohol Hand Rub Not applicableMfg 2020-03 · Exp 2024-03 Identification of Ethyl Alcohol Remarks:- 1) Sample contains 54.54%v/v Isopropyl Alcohol where as the label claim stated more than 75%v/v Ethyl Alcohol IP 2) There is colour variation in bottles from dark blue to light blueIdentification RDTL ChandigarhState lab Apr 2020

Batches reported as suspected spurious under this label

CDSCO's spurious-drug alerts list batches that purport to be made by a company but are suspected counterfeits. The labelled manufacturer's reply is shown where CDSCO published it.

ProductBatchReported byFirm's replyAlert
Cefixime Dispersible Tablets IPTC2439CDL, KolkataThe actual manufacturer (as per label claim) has informed that the impugned batch of the product has not been manufactured by them and that it is a spurious drug.May 2026
L-Carnitine, L- Tartarate ,Mecobalamin & Folic Acid TabletsB95Y032SDTL, AssamThe actual manufacturer (as per label claim) has informed that the impugned batch of the product has not been manufactured by them and that it is a spurious drug.Apr 2026
Deflazacort Tablets 6 mg Defcort 613240334ARDTL, ChandigarhThe actual manufacturer (as per label claim) has informed that the impugned batch of the product has not been manufactured by them and that it is a spurious drug.Dec 2025

Right of reply. Manufacturers may submit a response or a laboratory re-test result; it is published unedited alongside this record. Submit a response.